TY - JOUR
T1 - Predicting Instability Risk Following Hemiarthroplasty for Femoral Neck Hip Fractures in Geriatric Patients
AU - Hoehmann, Christopher L
AU - Mubin, Nailah F
AU - Hinnenkamp, Glyn
AU - Modica, Edward J
AU - Eckardt, Patricia A
AU - Cuellar, John C
PY - 2023
Y1 - 2023
N2 - Background Although a rare complication, dislocation following hemiarthroplasty (HA) for a femoral neck hip fracture is associated with increased mortality, readmission, and possible revision surgery. To date many of the specific risk factors have been difficult to demonstrate. Patient factors, surgical factors, as well as morphological factors need to be assessed. Therefore, the purpose of this study was to elucidate the risk factors for dislocation of HA following femoral neck hip fractures in the geriatric population.
Methods This was a retrospective review of 270 patients who had hip fractures. Medical records between the years 2016 and 2022 informed binomial regression predictive models. The discriminative ability of variables in the final model and acetabular anteversion to predict dislocation was assessed with area under the curve (AUC) estimates.
Results Center edge angle (odds ratio 1.23), abduction angle (odds ratio 1.17), and depth width ratio (2.96e-11) were significant predictors of dislocation (P = .003, .028, and <.001, respectively). Center edge angle and depth width ratio (<44.1 ° and .298), respectively, were cut scores for risk. Dementia had a high discriminative of ability, as did men (AUC = 0.617, 0.558, respectively). Acetabular anteversion was not predictive of dislocation (P = .259) and theorized anteversion safe zones had poor discriminative ability with AUCs of 0.510 and 0.503, respectively.
Conclusions Morphological factors related to hip dysplasia and a shallow acetabulum, which can be assessed with a radiograph alone, were found to be predictors of instability following HA in the elderly. Hemiarthroplasty implant design and manufacturer, and also acetabular version did not contribute to instability risk.
AB - Background Although a rare complication, dislocation following hemiarthroplasty (HA) for a femoral neck hip fracture is associated with increased mortality, readmission, and possible revision surgery. To date many of the specific risk factors have been difficult to demonstrate. Patient factors, surgical factors, as well as morphological factors need to be assessed. Therefore, the purpose of this study was to elucidate the risk factors for dislocation of HA following femoral neck hip fractures in the geriatric population.
Methods This was a retrospective review of 270 patients who had hip fractures. Medical records between the years 2016 and 2022 informed binomial regression predictive models. The discriminative ability of variables in the final model and acetabular anteversion to predict dislocation was assessed with area under the curve (AUC) estimates.
Results Center edge angle (odds ratio 1.23), abduction angle (odds ratio 1.17), and depth width ratio (2.96e-11) were significant predictors of dislocation (P = .003, .028, and <.001, respectively). Center edge angle and depth width ratio (<44.1 ° and .298), respectively, were cut scores for risk. Dementia had a high discriminative of ability, as did men (AUC = 0.617, 0.558, respectively). Acetabular anteversion was not predictive of dislocation (P = .259) and theorized anteversion safe zones had poor discriminative ability with AUCs of 0.510 and 0.503, respectively.
Conclusions Morphological factors related to hip dysplasia and a shallow acetabulum, which can be assessed with a radiograph alone, were found to be predictors of instability following HA in the elderly. Hemiarthroplasty implant design and manufacturer, and also acetabular version did not contribute to instability risk.
KW - hemiarthroplasty
KW - dislocation
KW - acetabular anteversion
KW - safe zone
KW - risk zone
U2 - 10.1016/j.arth.2023.09.030
DO - 10.1016/j.arth.2023.09.030
M3 - Article
C2 - 37776983
JO - The Journal of Arthroplasty
JF - The Journal of Arthroplasty
ER -